Migration Testing for Food Packaging: What Buyers Must Specify

Migration testing for flexible food packaging: laboratory setup and film sample in food simulant

Migration testing is only useful if the specification says what was tested, in which simulant, at which time and temperature, and against which limit. Four items on paper decide if a passing report tells you anything about the film you bought. Buyers who specify them get comparable reports across suppliers; buyers who skip them collect documents that cannot answer an audit question.

Key Takeaways

  • Overall migration and specific migration answer different questions. A report that shows only one of them covers half of what a food contact file needs.
  • The simulant must match the fat, acid and alcohol profile of the real product, not the product category name.
  • Time and temperature in the test should bracket the worst realistic contact, including warehouse and transport exposure.
  • Where the sample was taken matters: printed surface, adhesive layer and food-contact layer migrate differently.

What migration testing covers

Migration testing measures what leaves the packaging and enters the food. In flexible film that movement is rarely a single event. Monomer residue, oligomers, slip and anti-block additives, ink components, adhesive hardener fragments and solvent residue can all travel through the sealant layer toward the food surface over time.

Two measurement families exist. Overall migration weighs the total non-volatile mass that moves into a simulant and reports it as a mass per area figure. Specific migration targets named substances and compares each against its own limit. A film can meet the overall figure and still fail on one specific substance, so the two are complementary rather than interchangeable.

Which substances to name in the specification

Name the substances your own risk assessment flagged, not the whole regulation. Typical entries in a flexible packaging file are primary aromatic amines from certain ink and adhesive systems, epoxy derivatives from some laminating adhesives, caprolactam where polyamide is present, and specific additives carried in the sealant layer. If your product is fatty or acidic, add the substances most sensitive to that environment.

Ask the converter which of these are relevant to the actual structure being quoted. A three-layer PE/foil/PE structure and a metallised PET/PE structure do not share the same risk list, and copying the list from a different project is a common source of both over-testing and blind spots.

Migration testing for flexible food packaging: laboratory setup and film sample in food simulant

Concept packaging visual generated for editorial use. Not a customer project, not a tested structure.

Choosing the simulant

Choose the simulant from the fat, acid and alcohol behaviour of the food, then confirm the pick with the lab. Aqueous products are usually represented by water-based simulants or dilute acetic acid. Fatty products need a fat simulant, and dry powders may not require a liquid simulant at all. Alcoholic products add ethanol concentration as a variable.

The practical failure here is testing a sauce as if it were a neutral liquid because it sits in the same pouch style as a beverage. A sauce with a visible oil phase reaches the same film with a different migration driver. When the product is a composite, such as a powder with a fat-based coating, describe both phases to the lab rather than picking the more convenient one.

What conditions should the test bracket?

Set conditions to cover the worst realistic contact, then add margin. Standard condition sets exist for short-term, long-term and high-temperature contact, and the right pick depends on shelf life plus the temperatures the packed product actually sees in storage, transport and retail. A pouch sold through ambient channels and a pouch that crosses a hot summer container both need their own justification.

Two omissions recur on purchase orders. The first is forgetting the filling temperature: hot filling can push the contact condition well above the ambient assumption. The second is treating retort or pasteurisation as a separate compliance topic and not adding it to the migration test matrix, so the report covers ambient storage only.

Sampling location and finished form

Specify the sample location and the finished form. Migration results depend on the layer that touches food, the print coverage on the reverse side, the adhesive coat weight and the curing history. A lab sample cut from an unprinted trim area does not represent a heavily inked pouch that was laminated and then stored for two weeks.

Ask for the sample to be taken from production material of the same structure, same ink coverage band and same adhesive batch as the shipment. When the artwork changes, when the ink supplier changes, or when the adhesive is switched to a different chemistry, the previous report stops being evidence for the new film.

How to read the report before approval

Check four things before signing off. First, the structure on the report must match the structure in the quotation. Second, the simulant and condition must match what you specified. Third, each result must be compared against the limit for that substance, not merely reported as a number. Fourth, the test date and the sample identification must tie back to a batch you can trace.

Two further details are easy to miss. One is the contact-area convention: labs report per square decimetre, and two reports can only be compared when both use the same convention. The other is the reporting limit. A result written as below a certain value only counts as evidence if that value sits far enough under the regulatory limit to be meaningful.

Ask the lab to state the reporting limit for each substance, and read rollstock film specifications alongside the test matrix so the two documents describe the same structure. The flexible packaging solutions overview shows how test requirements shift with product type. For what each measurement family covers, see food contact material migration testing explained. The United States framework behind these substance categories sits in the 21 CFR Part 175 indirect food additive regulations.

Where it applies

This applies to any flexible structure that touches food directly, including pouches, roll film, lidding and sachets, and to secondary packaging only when the food is likely to contact it. It does not replace organoleptic testing, seal integrity testing or shelf-life trials. A migration report says nothing about the seal surviving a drop test, and nothing about how the product tastes after six months.

What a test report cannot settle

Non-food uses such as detergent or lubricant pouches fall outside this scope; those have their own chemical resistance and transport questions, which sit in a different part of the specification. Within food contact, the report also stays silent on seal strength, barrier and shelf life, each of which needs its own test plan and its own acceptance criterion.

Conclusion

Treat migration testing as a specification exercise, not a certificate to collect. Write the substance list, simulant, condition set and sample location into the purchase specification before the first order, and require the report to be traceable to the batch that was shipped. If the film structure, ink system or adhesive chemistry changes, re-test rather than reuse. The discipline costs a page of paperwork at the quotation stage and saves a re-test at the shipment stage.

Frequently Asked Questions

Does a passing overall migration result mean the film is compliant?

No. A pass on overall migration only shows that total non-volatile transfer stayed within the overall limit. It says nothing about individual substances with their own limits, such as primary aromatic amines or caprolactam. Ask for the specific migration results on the substances your risk assessment named, and check that each one is compared against its own limit rather than merely listed as a measured value.

Can a supplier reuse a migration report from a similar project?

Only when the structure, ink coverage, adhesive chemistry and sample condition are genuinely the same. Similar-looking pouches often differ in sealant grade or adhesive system, and either change alters what migrates. Ask the converter to state in writing which variables are identical; if the artwork changed or a new adhesive was introduced, order a fresh test instead of accepting the older report.

How much film does a laboratory need for migration testing?

The quantity depends on the lab’s surface-area method and on how many conditions are being run, so confirm the figure with the lab before cutting samples. What matters more than the total area is consistency: samples should come from one production run with even ink coverage. Sending a mix of trim offcuts and finished pouches produces results that cannot be traced back to a single structure.

Should the test be repeated for every production batch?

No, not for every batch. Repeat when something upstream changes: a new film structure, a different ink or adhesive supplier, a revised cure schedule, or a new product with a different fat or acid profile. Between those changes, batch-to-batch control is normally handled by incoming material checks and supplier certificates, with process records covering the cure and drying steps. Our guide to solvent retention in laminated film covers the process side of that control, which is where most unexplained rises in transfer originate.